800G OSFP DR8 SM MPO12 Optical Transceiver IB

Features

  • Form Factor: Hot-pluggable OSFP800 form factor
  • Data Rate: Aggregate data rate of 850 Gb/s and Breakout data rate of 106.25 Gb/s
  • Optical Interface: Compliant to 2×400GBASE-DR4 and 8x100GBASE-DR
  • Electrical Interface: Compliant to 2×400GAUI-4 and 8x100GAUI-1
  • Management Interface: I2C management interface
  • Reach: Up to 500m over MPO/APC single mode fiber
  • Power consumption: 16 W max
  • Operating case temperature: 0 ~ 70 ℃
  • Power Supply: Single 3.3V power supply

Compliance
  • Form Factor: OSFP MSA Rev 5.0 
  • Optical: IEEE802.3cd /IEEE802.3bs 
  • Electrical: IEEE802.3ck 
  • Firmware: CMIS 5.2 
  • Environment: RoHS 
  • Stability: GR-468-CORE

Applications
  • 800Gb/s Ethernet 
  • Data Center




  • Product Detail

OSFP 800G DR8 SM MPO12 IB Transceiver

NVIDIA twin port transceiver
800G ,2xNDR, OSFP, 2xMPO12 APC, 1310nm SMF, up to 100m, finned.


Functional Block Diagram

800G OSFP DR8


General Description

The 800G OSFP DR8 are high-performance, cost-effective transceivers designed for utilization in 800 Gigabit Ethernet links over 500 meters. On transmitter side, the module converts eight channels of 53.125 GBaud (PAM4) electrical data to eight channels of parallel optical signals with data rate of 53.125 GBaud (PAM4). At receiver side, the module converts eight channels of parallel optical signals with data rate of 53.125 GBaud (PAM4) into eight channels of 53.125 GBaud(PAM4) electrical output data.


The product is designed according to the OSFP MSA. It is designed to meet the harshest external operating conditions including temperature, humidity and EMI interference.


Absolute Maximum Ratings and Recommended Operating Conditions

Absolute Maximum Ratings

Parameter

Symbol

Min

Typical

Max

Unit

Storage Temperature

Ts

-40


85

°C

Relative Humidity (non-condensation)

RH

15


85

%

Supply Voltage

Vcc

-0.5


3.6

V

Optical Input Power, per Lane

PIN



5.0

dBm


Recommended Operating Conditions

Parameter

Symbol

Min


Max

Unit

Operating Case Temperature

TC

0


70

°C

Signaling Rate, each lane



53.125


GBd

Data Rate Accuracy


-100


100

ppm

Power Supply Voltage

VCC

3.135

3.3

3.465

V

Pre-FEC Bit Error Ratio




2.4E-4


Transmission Distance




500

m


Optical Specifications

Optical Transmitter

Transmitter optical characteristics

Parameter

Symbol

Min

Typical

Max

Unit

Signaling rate, each lane

SR

53.125+/-100ppm

GBd

Modulation format


PAM4


Lane wavelength

λ

1304.5

1311.0

1317.5

nm

Side-mode suppression ratio

SMSR

30



dB

Average launch power, each lanea

AOPTX

-2.9


4.0

dBm

Outer Optical Modulation

Amplitude (OMAouter), each laneb

OMATX

-0.8



dBm

Launch power in OMAouter minus TDECQ, each lane


-2.2



dBm

Transmitter and dispersion eye closure

 for PAM4, each lane

TDECQ



3.4

dB

Average launch power of OFF transmitter, each lane

AOPOFF



-15

dBm

Extinction ratio, each lane

ER

3.5



dB

RIN21.4OMA




–136

dB/Hz

Optical return loss tolerance

RLTol



21.4

dB

Transmitter reflectancec

Reflectance_

Tx



-26

dB

Note:

a. Average launch power, each lane (min) is informative and not the principal indicator of signal strength. A transmitter with launch power below this value cannot be compliant; however, a value above this does not ensure compliance.

b. Even if the TDECQ < 1.4 dB, the OMAouter (min) must exceed these values.

c. Transmitter reflectance is defined looking into the transmitter.

3.2 Optical Receiver


Receiver optical characteristics

Parameter

Symbol

Min

Typical

Max

Unit

Signaling rate, each lane

SR

53.125+/-100ppm

GBd

Modulation format


PAM4

-

Lane wavelengths

λ

1304.5

1311.0

1317.5

nm

Damage threshold, each lanea

DThd

5



dBm

Average receive power, each laneb

AOPRX

-5.9


4

dBm

Receiver reflectance

Reflectance_

Rx



-26

dB

Receiver sensitivity (OMAouter), each lanec

RxSens



-4.4

dBm

Stressed receiver sensitivity (OMAouter), each laned

SRS



-1.9

dBm

Conditions of stressed receiver sensitivity test:e

Stressed eye closure for PAM4 (SECQ), lane under test



3.4


dB

OMAouter of each aggressor lane



4.2


dBm

Rx LOS

LOS Assert

LOSA

-15


-7.9

dBm

LOS De-assert

LOSD



-7.4

dBm

LOS Hysteresis

LOSH

0.5


5

dB

Notes:

a. The receiver shall be able to tolerate, without damage, continuous exposure to an optical input signal having this average power level. The receiver does not have to operate correctly at this input power.

b. Average receive power, each lane (min) is informative and not the principal indicator of signal strength. A received power below this value cannot be compliant; however, a value above this does not ensure compliance.

c. Receiver sensitivity (OMAouter), each lane (max) is informative and is defined for a transmitter with SECQ of 0.9 dB.

d. Measured with conformance test signal at TP3 for the BER = 2.4E-4.

e. These test conditions are for measuring stressed receiver sensitivity. They are not characteristics of the receiver.



Digital Diagnostic Monitor Accuracy

The following characteristics are defined over recommended operating conditions.

Parameter

Accuracy

Unit

Internally Measured Transceiver Temperature

+/-3

Internally Measured Transceiver Supply Voltage

+/-3

%

Measured Tx Bias Current

+/-10

%

Measured Tx Output Power

+/-3

dB

Measured Rx Received Average Optical Power

+/-3

dB



Pin Assignment and Description

The OSFP module pinout and connector pin list are as follows:

800G OSFP DR8


Mechanical Dimensions

Package dimensions in mm are specified in OSFP MSA.

800G OSFP DR8

Package dimensions


Ordering Information

Part Number

Temperature

Range

Distance

Media Connector

Fiber Type

E/O

O/E

R12OSFP-800G-DR8

0 to 70

500m

Dual MPO-12

SMF

Siph PIC

Siph PD

R16OSFP-800G-DR8

0 to 70

500m

MPO-16

SMF

Siph PIC

Siph PD



Want to know about this product?

SEND A MESSAGE
Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products
800G OSFP SR8 MM MPO12 Optical Transceiver IB 800G OSFP SR8 MM MPO12 Optical Transceiver IB
Features OSFP Serial Optical Interface 8x100G PAM4 retimed 800GAUI-8 electrical interface Dual MPO-12 APC connector and MPO16 APC connector are provided 8 channel VCSEL arrays and 8 channels PIN photo detector arrays Maximum link length of 60m on OM3 or 100m on OM4 OSFP MSA Compliant Hot Pluggable OSFP form factor Compliant to OSFP Module Specification Rev 5.0 Compliant with CMIS 5.2 Support Protocol Compliant with IEEE 802.3db Compliant to IEEE 802.3ck Low Power Consumption Less than 14W in temperature range of 0 to 70℃ Applications 800GBASE-SR8 800G Ethernet Data center
Mechanical Fiber Optical Switch 1X8 900-1700nm 600um Mechanical Optical Switch 0.5m fiber, SMA905 connectors
Features Low Loss and High Reliability Serial Interface (RS-232)  Modularized Design Epoxy-free on Optical Path Applications Ring Network Remote Monitoring in Optical Network Testing of Fiber Optical Component
10G SFP+ Transceiver SFP+ 10G BIDI 100KM 1490/1550nm Optical Transceiver
SFP+ 10G BIDI 100KM optical transceiver module, support 10Gb/s and up to 100 km transmission on one core fiber. It works in high-speed IDC connection solutions, 5G network front-haul solution, network switch, PTN, OTN and so on. Features: Supports 9.95 to 11.3Gb/s bit rates Hot-Pluggable Single LC for Bi-directional Transmission cooled EML transmitter, APD photo-detector SMF links up to 100km 2-wire interface for management specifications compliant with SFF 8472 digital diagnostic monitoring interface Power Supply: +3.3V Power consumption<3W Temperature Range: 0~ 70°C RoHS compliant Applications: 10GBASE-ZR/ZW Ethernet SONET OC-192 / SDH 10G Fibre channel
25G SFP28 Transceiver 25G SFP28 CWDM Optical Transceiver
25G SFP28 CWDM optical transceiver module, support 25Gb/s and up to 10 km transmission, it works in high-speed IDC connection solutions, 5G network front-haul solution, and so on.
China SOA Amplifier SOA: 100G semiconductor optical amplifier board
40G 100G SOA Amplifier, Support O-band, 1260~1340nm, 14dB Gain, 10dB Max output, used in 10G/40G/100G network, Network monitor.
MPO TO  LC 4 Channels MPO TO Dual LC Device 2U Rack
48 Cores MPO to 48 LC/UPC 2*24 Cores MPO to 24 LC/UPC 12 Cores MPO to 12 LC/UPC 19 inch 2U Rack
Optical transport network Optical Transmission Network System OTN1000
Huge capacity transmission Excellent 100G transmission performance Flexible and comprehensive service access capability Telecom Reliable protection Excellent structure, convenient and easy to maintain
32CH DWDM MUX DEMUX 150GHz 32CH DWDM MUX DEMUX 1529.553nm-1566.723nm with Monitor Port,LC/UPC 1U Rack
IL<6.0dB , 100GHZ DWDM AAWG Technology Fully Compatible with All ITU-T 1G/10G/25G/40G/100G DWDM Optics Passive devices, No Power No Cooling Required Support Metro, Regional and Long Haul DWDM Networks
Leave A Message
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact