The 100G LR1 Single Lambda QSFP28 Optical Transceiver Module is designed for use in 100GBASE Ethernet throughput up to 10km over single mode fiber (SMF) using a wavelength of 1290nm or 1270/1290/1310/1330 via duplex LC connectors. So can be used 4x100G QSFP28 CWDM transceiver and one 4CH CWDM MUX(1270~1330nm) up to 400G transmission on two core fiber(SMF), 2-10KM distance between two Data Center
Features
NRZ Host side or 4x26.56Gbps NRZ Host side (close Media-side KP1 FEC inside Module)
100GBASE-LR1 QSFP28 Single Lambda 1271/1291/1311/1331nm 10km DOM Duplex LC SMF Optical Transceiver Module
FIBERWDM’s 100G LR1 single lambda 1271/1291/1311/1331nm10km QSFP28 transceiver is designed to transmit and receive serial optical data links up to 106.25Gbps data rate by PAM4 modulation format over single-mode fiber. It is a small-form- factor hot pluggable transceiver module integrated with the high performance cooled EML(CWDM wavelength available) laser and high sensitivity PIN receiver.
Ordering Information
Part No |
Specifications |
Application Code |
||||||
Pack |
Data rate |
Tx |
Pout |
Rx |
S(OMA) |
Reach |
||
RQ-100G-LR1-27 |
QSFP28 |
106.25Gb/s |
1271nm Cooled EMA DFB-LD |
-1.9~4.8dBm |
PIN |
<-6.1dBm |
10km |
100GBASE- LR |
RQ-100G-LR1-29 |
QSFP28 |
106.25Gb/s |
1291nm Cooled EMA DFB-LD |
-1.9~4.8dBm |
PIN |
<-6.1dBm |
10km |
100GBASE- LR |
RQ-100G-LR1-31 |
QSFP28 |
106.25Gb/s |
1311nm Cooled EMA DFB-LD |
-1.9~4.8dBm |
PIN |
<-6.1dBm |
10km |
100GBASE- LR |
RQ-100G-LR1-33 |
QSFP28 |
106.25Gb/s |
1331nm Cooled EMA DFB-LD |
-1.9~4.8dBm |
PIN |
<-6.1 dBm |
10km |
100GBASE- LR |
Absolute Maximum Ratings
Parameter |
Symbol |
Unit |
Min |
Max |
Storage Temperature Range |
Ts |
oC |
-40 |
+85 |
Relative Humidity |
RH |
% |
5 |
85 |
Power Supply Voltage |
Vcc |
V |
-0.5 |
+3.6 |
Operating Case Temperature Range |
Tc |
oC |
-5 |
75 |
Receiver Damage Threshold Per Lane |
Pdag |
dBm |
5.8 |
|
Recommended Operating Conditions
Parameter |
Units |
MIN. |
TYP. |
MAX. |
Notes |
Recommended Operating Conditions |
|||||
Operating Case Temperature |
°C |
0 |
|
+70 |
|
Power Supply Voltage |
V |
3.135 |
3.3 |
3.465 |
|
Data Rate(Electrical) |
Gbps |
25.781 25*4 |
26.5625*4 |
|
|
Data Rate(Optical) |
Gbps |
|
106.25 |
|
|
Link Distance with G.652 |
Km |
|
|
10 |
|
High Speed Electrical Specification
100G LR1-10 QSFP28 high speed electrical interface compliant to CEI-28G-VSR.
Parameter |
Unit |
Min |
Typ |
Max |
Notes |
||||
Transmitter Electrical Input from Host at TP1a |
|||||||||
Differential data input swing |
mV |
|
|
900 |
|
||||
differential impedance |
Ω |
|
100 |
|
|
||||
Differential termination mismatch |
% |
|
|
10 |
|
||||
Receiver Electrical Output to Host at TP4 |
|||||||||
Differential data input swing |
mV |
|
|
900 |
|
||||
Eye height,differential output |
mV |
228 |
|
|
|
||||
Eye width ,output |
UI |
0.57 |
|
|
|
||||
differential impedance |
Ω |
|
100 |
|
|
||||
Differential termination mismatch |
% |
|
|
10 |
|
Transmitter Optical Specification
Parameter |
Units |
MIN. |
TYP. |
MAX. |
Notes |
Transmitter Rate |
GBd |
|
53.125+/- 100ppm |
|
PAM4 |
Lane center WL |
nm |
1264.5 |
|
1277.5 |
RQ-100G-RL1-27 |
1284.5 |
|
1297.5 |
RQ-100G-RL1-29 |
||
1304.5 |
|
1317.5 |
RQ-100G-RL1-31 |
||
1324.5 |
|
1337.5 |
RQ-100G-RL1-33 |
||
Side-mode suppression Ratio |
dB |
30 |
|
|
|
Optical output power |
dBm |
-1.9 |
|
4.8 |
|
Optical modulation amplitude |
dBm |
1.1 |
|
5 |
For TDECQ < 1.4 dB |
TDECQ-0 .3 |
|
5 |
For 1.4dB<TDEC Q<TEDCQ(m ax) |
||
Transmitter and dispersion penalty eye closure for PAM4 (TDECQ) |
dB |
|
|
3.4 |
|
TECQ |
dB |
|
|
3.4 |
|
TDECQ-TECQ |
dB |
|
|
2.5 |
|
Extinction ratio |
dB |
3.5 |
|
|
|
Average launch power of OFF transmitte |
dB |
|
|
-15 |
|
Transmitter over/under-shoot |
% |
|
|
22 |
|
Optical return loss tolerance |
dB |
|
|
15.6 |
|
Transmitter reflectance |
dB |
|
|
-26 |
|
Transmitter transition time |
ps |
|
|
17 |
|
RINx OMA (max)where x is the optical return loss tolerance (max) |
dB/Hz |
|
|
-136 |
|
Receiver Optical Specification
Parameter |
Units |
MIN. |
TYP. |
MAX. |
Notes |
Receive Rate |
GBd |
|
53.125+/-1 00ppm |
|
PAM4 |
Lane center WL |
nm |
1260 |
|
1610 |
|
Damage threshold |
dBm |
5.8 |
|
|
|
Average receive power |
dBm |
-8.2 |
|
4.8 |
|
Receiver power(OMA) |
dBm |
|
|
5 |
|
Receive Sensitivity(OMA) |
dBm |
|
|
-6.1 |
For TDECQ <1.4dB@BER2.4e-4 |
|
|
-7.5+T ECQ |
For 1.4dB<TDECQ<TEDCQ(max) @BER 2.4e-4 |
||
Stressed Sensitivity (OMA) |
dBm |
|
|
-4.1 |
|
Receiver reflectance |
dB |
|
|
-26 |
|
Conditions of stressed receiver sensitivity test: |
|||||
Stressed eye closure for PAM4(test conditions) |
dB |
|
3.4 |
|
SECQ |
SECQ-10*lgCeq |
dB |
|
|
3.4 |
|