240816 Fiberwdm- commonly used optical module performance and parameter indicators
Aug 17, 2024240816 Fiberwdm- commonly used optical module performance and parameter indicators
(Fiberwdm All rights Reserved)
FIBERWDM, based on years of accumulation in the field of transmission, provides multi-specification optical module applications for data centers, enterprise networks, data communication equipment manufacturers, high-definition video and other fields. Optical module types include:
1 g, 10 g, 25 g, 40 g, 100 g, 200 g, 400 g, 800 g, including encapsulation type 1 x9, SFP, SFP + / XFP, SFP28, QSFP +, QSFP28, QSFP - DD, etc., welcome the masses of customer consultation and contact!
Fiberwdm-Optical module Performance and parameter comparison table (Part) |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
Type |
Rui Dong optical module model |
Package Mode |
Rate |
Mode |
Wavelength |
Transmission distance |
TX Power |
RX Power |
Receiving tube |
laser |
Interface type |
1.25G Dual |
RSPD-03M055-850 |
SFP |
1.25G |
MM |
850nm |
550M |
(-9~-3)dBm |
≤-24dBm |
PIN |
VCSEL |
LC |
RSPD-03S10-1310 |
SFP |
1.25G |
SM |
1310nm |
10KM |
(-9~-3)dBm |
≤-22dBm |
PIN |
FP |
LC |
|
RSPD-03S40-1310 |
SFP |
1.25G |
SM |
1310nm |
40KM |
(-5~0)dBm |
≤-24dBm |
PIN |
DFB |
LC |
|
RSPD-03S40-1550 |
SFP |
1.25G |
SM |
1550nm |
40KM |
(-5~0)dBm |
≤-24dBm |
PIN |
DFB |
LC |
|
RSPD-03S80-1550 |
SFP |
1.25G |
SM |
1550nm |
80KM |
(0~5)dBm |
≤-24dBm |
PIN |
DFB |
LC |
|
RSPD-03S120-1550 |
SFP |
1.25G |
SM |
1550nm |
120KM |
(1~5)dBm |
≤-31dBm |
APD |
DFB |
LC |
|
RSPD-03C40-XX |
SFP |
1.25G |
SM |
CWDM |
40KM |
(-5~0)dBm |
≤-24dBm |
PIN |
DFB |
LC |
|
RSPD-03C80-XX |
SFP |
1.25G |
SM |
CWDM |
80KM |
(0~5)dBm |
≤-24dBm |
PIN |
DFB |
LC |
|
RSPD-03C120-XX |
SFP |
1.25G |
SM |
CWDM |
120KM |
(0~5)dBm |
≤-31dBm |
APD |
DFB |
LC |
|
RSPD-03D40-CXX |
SFP |
1.25G |
SM |
DWDM |
40KM |
(-2~3)dBm |
≤-24dBm |
PIN |
DFB |
LC |
|
RSPD-03D80-CXX |
SFP |
1.25G |
SM |
DWDM |
80KM |
(0~5)dBm |
≤-24dBm |
PIN |
DFB |
LC |
|
RSPD-03D120-CXX |
SFP |
1.25G |
SM |
DWDM |
120KM |
(1~5)dBm |
≤-31dBm |
APD |
DFB |
LC |
|
1.25G Single |
RSPD-03BD10-3155 |
SFP |
1.25G |
SM |
1310T/1550R |
10KM |
(-9~-3)dBm |
-22dBm |
PIN |
FP |
LC |
RSPD-03BD10-5531 |
SFP |
1.25G |
SM |
1550T/1310R |
10KM |
(-9~-3)dBm |
-22dBm |
PIN |
DFB |
LC |
|
RSPD-03BD40-3155 |
SFP |
1.25G |
SM |
1310T/1550R |
40KM |
(-5~0)dBm |
-23dBm |
PIN |
DFB |
LC |
|
RSPD-03BD40-5531 |
SFP |
1.25G |
SM |
1550T/1310R |
40KM |
(-5~0)dBm |
-23dBm |
PIN |
DFB |
LC |
|
RSPD-03BD80-4955 |
SFP |
1.25G |
SM |
1490T/1550R |
80KM |
(-2~3)dBm |
-24dBm |
PIN |
DFB |
LC |
|
RSPD-03BD80-5549 |
SFP |
1.25G |
SM |
1550T/1490R |
80KM |
(-2~3)dBm |
-24dBm |
PIN |
DFB |
LC |
|
RSPD-03BD120-4955 |
SFP |
1.25G |
SM |
1490T/1550R |
120KM |
(1~5)dBm |
-31dBm |
APD |
DFB |
LC |
|
RSPD-03BD120-5549 |
SFP |
1.25G |
SM |
1550T/1490R |
120KM |
(1~5)dBm |
-31dBm |
APD |
DFB |
LC |
|
SFP+ 10G Dual |
RSPD-10M03-850 |
SFP+ |
10G |
MM |
850nm |
300M |
(-6.5~-1)dBm |
≤-11.1dBm |
PIN |
VCSEL |
LC |
RSPD-10GS10-1310 |
SFP+ |
10G |
SM |
1310nm |
10KM |
(-6~+0.5)dBm |
≤-14dBm |
PIN |
DFB |
LC |
|
RSPD-10GS40-1310 |
SFP+ |
10G |
SM |
1310nm |
40KM |
(-1~+3)dBm |
≤-15dBm |
PIN |
DFB |
LC |
|
RSPD-10GS40-1550 |
SFP+ |
10G |
SM |
1550nm |
40KM |
(-1~+4)dBm |
≤-16dBm |
PIN |
EML |
LC |
|
RSPD-10GS80-1550 |
SFP+ |
10G |
SM |
1550nm |
80KM |
(0~+4)dBm |
≤-24dBm |
APD |
EML |
LC |
|
RSPD-10GC40-XX |
SFP+ |
10G |
SM |
CWDM (1470-1610) |
40KM |
(-1~+3)dBm |
≤-16dBm |
PIN |
EML |
LC |
|
RSPD-10GC80-XX |
SFP+ |
10G |
SM |
CWDM (1470-1610) |
80KM |
(0~+4)dBm |
≤-24dBm |
APD |
EML |
LC |
|
RSPD-10GD40-CXX |
SFP+ |
10G |
SM |
DWDM |
40KM |
(-2~+2)dBm |
≤-16dBm |
PIN |
EML |
LC |
|
RSPD-10GD80-CXX |
SFP+ |
10G |
SM |
DWDM |
80KM |
(0~+4)dBm |
≤-24dBm |
APD |
EML |
LC |
|
SFP+ 10G Single |
RSPD-10GBD10-2733 |
SFP+ |
10G |
SM |
1270T/1330R |
10KM |
(-6~0.5)dBm |
-14dBm |
PIN |
DFB |
LC |
RSPD-10GBD10-3327 |
SFP+ |
10G |
SM |
1330T/1270R |
10KM |
(-6~0.5)dBm |
-14dBm |
PIN |
DFB |
LC |
|
RSPD-10GBD20-2733 |
SFP+ |
10G |
SM |
1270T/1330R |
20KM |
(-2~2)dBm |
-14dBm |
PIN |
DFB |
LC |
|
RSPD-10GBD20-3327 |
SFP+ |
10G |
SM |
1330T/1270R |
20KM |
(-2~2)dBm |
-14dBm |
PIN |
DFB |
LC |
|
RSPD-10GBD40-2733 |
SFP+ |
10G |
SM |
1270T/1330R |
40KM |
(0~5)dBm |
-15dBm |
PIN |
DFB |
LC |
|
RSPD-10GBD40-3327 |
SFP+ |
10G |
SM |
1330T/1270R |
40KM |
(0~5)dBm |
-15dBm |
PIN |
DFB |
LC |
|
RSPD-10GBD60-2733 |
SFP+ |
10G |
SM |
1270T/1330R |
60KM |
(0~5)dBm |
-20dBm |
APD |
DFB |
LC |
|
RSPD-10GBD60-3327 |
SFP+ |
10G |
SM |
1330T/1270R |
60KM |
(0~5)dBm |
-20dBm |
APD |
DFB |
LC |
|
RSPD-10GBD80-4955 |
SFP+ |
10G |
SM |
1490T/1550R |
80KM |
(0~5)dBm |
-21dBm |
APD |
EML |
LC |
|
RSPD-10GBD80-5549 |
SFP+ |
10G |
SM |
1330T/1270R |
80KM |
(0~5)dBm |
-21dBm |
APD |
EML |
LC |
|
QSFP+ 40G |
RQ-40GSR4 |
QSFP+ |
40G(4*10G) |
MM |
850nm |
150M |
(-7~1.9)dBm per channel |
≤-10.3dBm per channel |
PIN |
VCSEL |
MPO |
RQ-40GLR4 |
QSFP+ |
40G(4*10G) |
SM |
CWDM4 |
10KM |
(-7~2.3dBm per channel |
≤-11dBm per channel |
PIN |
DFB |
LC |
|
RQ-40GER4 |
QSFP+ |
40G(4*10G) |
SM |
CWDM4 |
40KM |
(-2.7~4.5)dBm per channel |
≤-21dBm per channel |
APD |
EML |
LC |
|
RQ-40GZR4 |
QSFP+ |
40G(4*10G) |
SM |
CWDM4 |
80KM |
(1~6)dBm per channel |
≤-25dBm per channel |
APD |
EML |
LC |
|
QSFP28 100G |
RQ-100GSR4 |
QSFP28 |
100G(4*25G) |
MM |
850nm |
100M |
(-8.4~2.4)dBm per channel |
≤-10.3dBm per channel |
PIN |
VCSEL |
MPO |
RQ-100GLR4 |
QSFP28 |
100G(4*25G) |
SM |
LWDM4 |
10KM |
(-4.3~4.5dBm per channel |
≤-10.6dBm per channel |
PIN |
EML |
LC |
|
RQ-100GER4 |
QSFP28 |
100G(4*25G) |
SM |
LWDM4 |
40KM |
(-2.7~4.5)dBm per channel |
≤-18.5dBm per channel |
APD |
EML |
LC |
|
RQ-100GZR4 |
QSFP28 |
100G(4*25G) |
SM |
LWDM4 |
80KM |
(2~6.5)dBm per channel |
≤-28dBm per channel |
APD |
EML |
LC |
|
Note:All long APD receiving modules must be equipped with optical attenuators during local-loop testing to avoid strong light damaging the receiving devices |
General keywords:
Passive wave division: CWDM,DWDM, Wavelength division Equipment, Wavelength Division multiplexer, MUX/DEMUX, high speed, the TAWG/AAWG, flat-roofed type AWG, gaussian type AWG, 100 GHZ / 200 GHZ / 50 GHZ / 75 GHZ / 150 GHZ, 40, 48 ch / 96 ch/ch / 120 ch / 64 ch / 32 ch AWG, FWDM, LWDM,MWDM,LAN-WDM, SWDM, O-band WDM, CEx-WDM, Fiber Bragg Grating reflector, Fiber Bragg Grating array waveguide, Rack-mounted passive wavelength division, interleaver, Comb filter, mini wavelength division module, CCWDM, Ultra MINI WDM,RAMAN WDM, Raman WDM, GPON, EPON,XGS-PON, NG-PON,XG-PON, 50G PON, FTTR
Optical fiber transmission equipment: Wavelength division transmission, 200G/400G DCI, EDFA, SOA, RFA Raman amplifier, fiber long distance transmission, OLP, optical line protection, OBP, optical bypass protection, bypass device, power cut through, fiber active/standby route protection, semi-active wavelength division, PON remote, PON aggregation remote, Optical cable detection system, 5G stretch, optical fiber expansion, DCM dispersion compensation, data center interconnection DCI, bare fiber interconnection, VOA board, dimmable attenuator, OEO/OTU board, 40G business board, 100G business board
Optical splitter: FBG taper splitter, PLC optical splitter, wave splitter, TAP-PD, multi-mode splitter, multi-mode PLC
Optical switch: mechanical optical switch, MEMS optical switch, magneto-optical switch, optical routing equipment, optical crossover, optical switching, OXC optical matrix, optical switch switching equipment
Optical module: 1X9 optical module, SFP/SFP+/XFP optical module, QSFP+40G optical module, QSFP28 100G optical module, 200G optical module, 400G optical module, 800G optical module, QSFP-DD, QSFP56, QSFP112, OSFP, AI computing power optical module, SDI optical module, HD video optical module, single transmission and single receiving optical module, wave division optical module, CWDM optical module, DWDM optical module, industrial optical module, military optical module; 25G optical module, 40G optical module, Fiberchannel, 8G/16G/32G FC optical module, 12G SDI optical module, CFP to QSFP28 conversion module
High speed cable: DAC, AOC, ACC,AEC,Mini-SAS, HDMI AOC
Integrated cabling: optical jumper, MPO/MTP jumper, armored optical jumper, base station pull high beam jumper, field cable assembly, multi-core cable jumper, ODF fiber distribution frame, fiber connector box, 144 core high density fiber distribution frame, photoelectric composite cable
Optical devices: Circulator, passive dual fiber to single fiber, passive single multimode conversion, optical isolator, polarization-preserving device, polarization-preserving coupler, polarization-preserving circulator, polarization-preserving jumper, polarization-preserving isolator, PBC/PBS beam binder/splitter, polarization-preserving CWDM, polarization-preserving DWDM
Network security: OTAP rack-mounted splitter, TAP shunt, aggregation shunt, traffic replication, spectral replication, one-way isolation, fiber optic network card
Access equipment: Optical transceiver, protocol converter, optical fiber transceiver, photoelectric converter, PCM equipment, telephone optical transceiver, PDH optical transceiver, video optical transceiver, industrial transceiver, Industrial switch, POE switch, POE transceiver.